How to Fix Canon Pixma iP1500 error Waste Ink Absorber Full


Operator Call Error (LED Blinking in Orange)
LED blinking: 8 times
Error: Waste ink absorber full or platen waste ink absorber full warning (approx. 95% of the maximum capacity)
Corrective action: Pressing the Resume/Cancel button will exit the error, and enable printing.

Service Call Error (LED Blinking in Orange and Green Alternately)
LED blinking: 7 times
Error: Waste ink absorber full or platen waste ink absorber full

Solution: Reset the printer



Reset Canon Pixma iP1500 error Ink Absorber Full

  • To reset error Waste ink absorber full, use GeneralTool for T3164 version 1.18
  • Download General Tool v1.18 (support Win XP, Vista, 7, 8, 8.1, 10)
  • Extract file and open GeneralTool
  • Load paper A4 or Letter

How to Reset Canon Pixma iP1500 with General Tool v.1.18


  • Select the connected USB port number from USB PORT (1)
  • Select TEST PATTERN 1 (2), and the shipment inspection pattern 1 will be printed.
  • In SET DESTINATION (3), select the applicable model name.“iP1500J” for Japan model, “iP1500E” for non-Japan models.
  • Click DEVICE ID (4), and confirm the model name indicated in the (5) area (iP_1500 for iP1500J, iP1500 for iP1550E). Or, confirm the model name on the shipment inspection pattern printout.
  • After marking the EEPROM CLEAR (6) checkbox, perform the shipment inspection pattern printing. The EEPROM will be reset.
  • In CLEAR WASTE INK COUNTER (7), select MAIN or PLATEN. The selected waste ink counter will be reset. MAIN resets the main waste ink counter. PLATEN resets the platen waste ink counter.
  • Click EEP-ROM INFORMATION (8). The EEP-ROM INFORMATION dialog box will open to display EEPROM information details.
  • Close the dialog box, close GeneralTool, Finish.